Manufacturer · Luoyang, ChinaExport & OEM support worldwide

sales@yuboo.com English

Thermal analysis · Carbon / silicon / Elemental analysis

HR-QC08Hot Metal Quality Analyzer

Carbon equivalent, carbon, silicon, and manganese from the cooling curve — a furnace-side check before the pour.

Grey ironDuctile ironCast ironSynthetic iron Application-specific configuration
Elemental analysis
HR-QC08
HR-QC08 hot metal quality analyzer for carbon silicon and carbon equivalent measurement YuBoo Instrument / Luoyang, China

01 / Why this configuration

Built around a real measurement decision.

The HR-QC08 reads the cooling curve of a melt sample and calculates carbon equivalent, carbon, silicon, manganese, nodularity, and tensile strength indicators. It gives the furnace team a fast decision before the iron is poured.

Carbon equivalent, carbon, silicon, and manganese from the cooling curve — a furnace-side check before the pour. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.

Carbon equivalent and cooling-curve analysis
Carbon, silicon, manganese, and nodularity indicators
Automatic calculation of addition amounts
15-inch colour display and curve records
Furnace-side check before pouring
Operator training and application support

02 / Configuration

Key specifications.

Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.

Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.

Request a configuration
MethodThermal analysis / cooling curve
MeasurementsCE%, C%, Si%, Mn%, SG%, Rm
Cycle timeApproximately 1 min 40 s
Display15-inch TFT colour display
PowerAC 220 V / 50 Hz / 200 W
OutputAutomatic addition calculation and curves
SampleMelt sample in a carbon-equivalent cup
ConfigurationBenchtop

Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.

03 / Where it fits

Applications and materials.

Elemental analysis supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.

See how we support the installation
  • Furnace-side carbon equivalent control
  • Carbon and silicon adjustment before the pour
  • Nodularity support in ductile iron
  • Automatic charge-addition calculation
  • Cooling-curve records for the heat
  • Operator decision support

Typical materials

Grey ironDuctile ironCast ironSynthetic iron

If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.

Before you specify

HR-QC08 — practical answers.

Still deciding? Send the material and the measurement target — we will reply with a practical next step.

Ask an application engineer
What is the HR-QC08 used for?

Carbon equivalent, carbon, silicon, and manganese from the cooling curve — a furnace-side check before the pour. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.

Which materials and sample forms does the HR-QC08 cover?

Typical materials: Grey iron, Ductile iron, Cast iron, Synthetic iron. Typical tasks: furnace-side carbon equivalent control, carbon and silicon adjustment before the pour. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.

What are the key specifications of the HR-QC08?

Starting point: method Thermal analysis / cooling curve; measurements CE%, C%, Si%, Mn%, SG%, Rm; cycle time Approximately 1 min 40 s. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.

How is the configuration confirmed before ordering?

Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.

Put it to work

Configure HR-QC08 around your material.

Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.