Inert gas fusion · O/N/H / Elemental analysis
ONH-6800Oxygen, Nitrogen & Hydrogen Analyzer
Inert-gas fusion with infrared and thermal-conductivity detection for oxygen, nitrogen, and hydrogen in metals.
ONH-6800
YuBoo Instrument / Luoyang, China
01 / Why this configuration
Built around a real measurement decision.
The ONH-6800 uses inert-gas fusion to release oxygen, nitrogen, and hydrogen from a metal sample. Infrared and thermal-conductivity detection then quantify the gases, giving a dedicated check for steel, cast iron, alloys, and other materials.
Inert-gas fusion with infrared and thermal-conductivity detection for oxygen, nitrogen, and hydrogen in metals. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.
02 / Configuration
Key specifications.
Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.
Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.
Request a configuration| Method | Inert gas fusion |
|---|---|
| Elements | Oxygen, nitrogen, hydrogen |
| Detection | Infrared absorption + thermal conductivity |
| Sample types | Steel, cast iron, alloys, copper, rare earth, inorganic materials |
| Configuration | Benchtop integrated system |
| Environment | 20–25 °C; RH <70% |
| Output | O / N / H concentration |
| Utilities | Argon (helium for O-only), graphite crucibles |
Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.
03 / Where it fits
Applications and materials.
Elemental analysis supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.
See how we support the installation- Oxygen and nitrogen in steel
- Hydrogen in cast and wrought alloys
- Cleanliness and gas-content checks
- Incoming material verification
- Process and heat-treat control
- Cross-method confirmation
Typical materials
If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.
Before you specify
ONH-6800 — practical answers.
Still deciding? Send the material and the measurement target — we will reply with a practical next step.
Ask an application engineerWhat is the ONH-6800 used for?
Inert-gas fusion with infrared and thermal-conductivity detection for oxygen, nitrogen, and hydrogen in metals. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.
Which materials and sample forms does the ONH-6800 cover?
Typical materials: Carbon steel, Alloy steel, Stainless steel, Cast iron. Typical tasks: oxygen and nitrogen in steel, hydrogen in cast and wrought alloys. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.
What are the key specifications of the ONH-6800?
Starting point: method Inert gas fusion; elements Oxygen, nitrogen, hydrogen; detection Infrared absorption + thermal conductivity. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.
How is the configuration confirmed before ordering?
Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.
Put it to work
Configure ONH-6800 around your material.
Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.