SDB-810 · 16-channel CCD · 130–700 nm / Spark OES
SDB-810Full-Spectrum CCD Direct-Reading Spectrometer
A benchtop full-spectrum spark OES with 16-channel CCD detection and 130–700 nm Paschen-Runge optics for multi-base metal analysis.
SDB-810
YuBoo Instrument / Luoyang, China
01 / Why this configuration
Built around a real measurement decision.
The SDB-810 is a full-spectrum spark OES for prepared solid metal samples. It uses a 16-channel Hamamatsu/Toshiba CCD (CMOS optional), 3,648 pixels per channel and 58,368 pixels in total, with a 400 mm Paschen-Runge optical system covering 130–700 nm. The optical chamber is thermostatted at 35 ±0.1 °C, and the digital dual-pulse source operates from 200 to 800 Hz.
A benchtop full-spectrum spark OES with 16-channel CCD detection and 130–700 nm Paschen-Runge optics for multi-base metal analysis. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.
02 / Configuration
Key specifications.
Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.
Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.
Request a configuration| Configuration | Vacuum or non-vacuum; non-vacuum covers Al, Mg and Zn |
|---|---|
| Detector | 16-channel CCD (Hamamatsu/Toshiba; CMOS optional); 3,648 px/channel; 58,368 px total |
| Optical system | Paschen-Runge / Rowland circle; 400 mm; 2,400 lines/mm |
| Wavelength range | 130–700 nm |
| Entrance slit | 10 µm coated slit |
| Optical chamber | 35 ±0.1 °C; vacuum below 2 Pa |
| Excitation source | Full-digital dual-pulse; 200–800 Hz; dual spark |
| Base coverage | Fe · Al · Cu · Zn · Sn · Pb · Mg · Ni · Ti · Co |
| Argon | 99.999%; inlet 0.25 MPa; flow <5 L/min; standby 0.2–0.5 L/min |
| Readout | 16-bit ADC; FPGA; 16 × 100k synchronous sampling |
| Computer | External Windows computer and printer |
| Power | 220 V ±10%, 50 Hz; 200–1000 VA; 10 A slow-blow fuse |
| Dimensions | 810 × 660 × 380 mm |
| Weight | Approx. 80 kg |
| Environment | 10–35 °C; RH 20–80%; no corrosive gas or heavy dust |
Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.
03 / Where it fits
Applications and materials.
Spark OES supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.
See how we support the installation- Multi-base metal analysis
- Furnace charge and melt control
- Incoming material verification
- Grade identification and sorting
- Final chemical verification
- Production records and certificates
Typical materials
If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.
Before you specify
SDB-810 — practical answers.
Still deciding? Send the material and the measurement target — we will reply with a practical next step.
Ask an application engineerWhat is the SDB-810 used for?
A benchtop full-spectrum spark OES with 16-channel CCD detection and 130–700 nm Paschen-Runge optics for multi-base metal analysis. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.
Which materials and sample forms does the SDB-810 cover?
Typical materials: Carbon steel, Aluminium alloys, Copper alloys, Nickel alloys. Typical tasks: multi-base metal analysis, furnace charge and melt control. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.
What are the key specifications of the SDB-810?
Starting point: configuration Vacuum or non-vacuum; non-vacuum covers Al, Mg and Zn; optical system Paschen-Runge / Rowland circle; 400 mm; 2,400 lines/mm; wavelength range 130–700 nm. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.
How is the configuration confirmed before ordering?
Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.
Put it to work
Configure SDB-810 around your material.
Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.