Manufacturer · Luoyang, ChinaExport & OEM support worldwide

sales@yuboo.com English

SDB-910 · 16-channel CCD · 120–800 nm / Spark OES

SDB-910Full-Spectrum CCD Direct-Reading Spectrometer

A benchtop full-spectrum spark OES with 16-channel CCD detection, 120–800 nm optics and a typical 10–30 second multi-base analysis.

Carbon steelAluminium alloysCopper alloysNickel alloysStainless steel Application-specific configuration
Spark OES
SDB-910
YuBoo SDB-910 full-spectrum CCD direct-reading optical emission spectrometer YuBoo Instrument / Luoyang, China

01 / Why this configuration

Built around a real measurement decision.

The SDB-910 is a full-spectrum spark OES for prepared solid metal samples. It uses a 16-channel CCD detector (Toshiba, Sony or Hamamatsu; back-illuminated CCD or CMOS optional), 3,648 pixels per channel and 58,368 pixels in total, with a 400 mm Paschen-Runge optical system covering 120–800 nm. The optical chamber is thermostatted at 35 ±0.1 °C, and the digital dual-pulse source operates from 100 to 1000 Hz.

A benchtop full-spectrum spark OES with 16-channel CCD detection, 120–800 nm optics and a typical 10–30 second multi-base analysis. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.

16-channel CCD (Toshiba/Sony/Hamamatsu; back-illuminated CCD or CMOS optional); 58,368 px total
Paschen-Runge; 400 mm; 2,400 lines/mm; 120–800 nm
10 µm entrance slit; optical chamber at 35 ±0.1 °C
Full-digital dual-pulse source; 100–1000 Hz; dual spark
Vacuum 0.1–5 Pa; molecular sieve and isolation valve
Bases plus pure Al, Cu, Zn, Sn and Pb

02 / Configuration

Key specifications.

Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.

Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.

Request a configuration
Detector16-channel CCD (Toshiba/Sony/Hamamatsu; back-illuminated CCD or CMOS optional); 3,648 px/channel; 58,368 px total
Optical systemPaschen-Runge / Rowland circle; 400 mm; 2,400 lines/mm
Wavelength range120–800 nm
Entrance slit10 µm coated slit
Optical chamber35 ±0.1 °C; vacuum 0.1–5 Pa
Excitation sourceFull-digital dual-pulse; 100–1000 Hz; dual spark
Base coverageFe · Al · Cu · Zn · Sn · Pb · Mg · Ni · Ti · Co; plus pure Al, Cu, Zn, Sn, Pb
Argon99.999%; inlet 0.25 MPa; flow <5 L/min; standby 0.2–0.5 L/min
Gas pathDual gas path, four nozzles; built-in flow meter
Readout16-bit ADC; FPGA; 16 × 100k synchronous sampling
ComputerExternal Windows computer and printer
Power220 V ±10%, 50 Hz; 200–1000 VA; 10 A slow-blow fuse
Dimensions880 × 720 × 410 mm
WeightApprox. 95 kg
Environment10–35 °C; RH 20–80%; no corrosive gas or heavy dust

Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.

03 / Where it fits

Applications and materials.

Spark OES supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.

See how we support the installation
  • Multi-base metal analysis
  • Furnace charge and melt control
  • Incoming material verification
  • Grade identification and sorting
  • Final chemical verification
  • Pure-metal and alloy verification

Typical materials

Carbon steelAluminium alloysCopper alloysNickel alloysStainless steelGrey ironDuctile ironLow-alloy steelLead alloysZinc alloysMagnesium alloysTitanium alloysCobalt alloysPure aluminiumPure copper

If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.

Before you specify

SDB-910 — practical answers.

Still deciding? Send the material and the measurement target — we will reply with a practical next step.

Ask an application engineer
What is the SDB-910 used for?

A benchtop full-spectrum spark OES with 16-channel CCD detection, 120–800 nm optics and a typical 10–30 second multi-base analysis. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.

Which materials and sample forms does the SDB-910 cover?

Typical materials: Carbon steel, Aluminium alloys, Copper alloys, Nickel alloys. Typical tasks: multi-base metal analysis, furnace charge and melt control. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.

What are the key specifications of the SDB-910?

Starting point: optical system Paschen-Runge / Rowland circle; 400 mm; 2,400 lines/mm; wavelength range 120–800 nm; entrance slit 10 µm coated slit. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.

How is the configuration confirmed before ordering?

Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.

Put it to work

Configure SDB-910 around your material.

Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.