LIBS / Lithium / Handheld series
SciAps Z-903Lithium, in the field.
A handheld lithium and geochemical LIBS with 190–950 nm coverage. It measures lithium and a broad element set in rocks, soils, ceramics, and other non-metallic samples.
SciAps Z-903
Specification confirmed at quotation
01 / Why this model
One question, answered properly.
The Z-903 is built for lithium and geochemistry rather than metals: 190–950 nm coverage, H to U including lithium, and a 5–6 mJ laser. It is the instrument for exploration teams reading rocks, soils, drill core and ceramics where a laboratory round trip costs weeks.
Best forLithium-bearing rocks, soils, ceramics, and geochemical exploration.
02 / Specification
Key numbers.
These are the figures that decide whether a reading is usable: spot size, element coverage, measurement time and excitation.
Send the material list and the decision the result has to support. We will confirm the configuration and the sample form.
Request a configuration| Method | LIBS · 1064 nm |
|---|---|
| Range | 190–950 nm |
| Elements | H–U including Li |
| Measurement | 1–10 s |
| Laser | 5–6 mJ · 50 Hz |
| Screen | 3.5-inch touchscreen |
Indicative specification for comparison. The datasheet and acceptance criteria are confirmed with the quotation.
03 / Where it fits
Applications and materials.
Choose the model on the element set and the sample form, not on the brand. If the material list is not here, send it before committing.
See how handover and training work- Lithium exploration and pegmatite screening
- Drill core and chip tray scanning
- Soil geochemistry surveys
- Ceramics, refractories and non-metallic sample screening
- Pathfinder element mapping in the field
Typical materials
The rest of the series
Same question, different coverage.
Pick by element coverage and spot size first, then by speed, ergonomics and the service route in your country.
All handheld models| Model | Method | Best for | Detail |
|---|---|---|---|
| SciAps X-50 | XRF · 7 mm² SDD | Alloy ID, coatings, precious metals, and RoHS screening — not the choice when Mg, Al, Si, S, or P matter. | View |
| SciAps X-200 | XRF · 20 mm² SDD | Scrap sorting, PMI, and alloy identification where aluminium and a wider element set matter. | View |
| K-5000T | XRF · Mg–U | Alloy ID, precious metals, pressure vessels, scrap recycling, and aerospace material verification. | View |
| Y-300 | LIBS · 1064 nm | Aluminium grade ID, recycled aluminium sorting, and PMI of aluminium components. | View |
| Y-400 | LIBS · 1064 nm | Carbon verification in stainless, alloy, and carbon steels, plus incoming and PMI checks. | View |
Before you specify
SciAps Z-903 — practical answers.
Still deciding? Send the material and the measurement target — we will reply with a practical next step.
Ask an application engineerCan it measure lithium directly in brine?
Not directly. Brines and liquids need sample preparation and a laboratory method. The Z-903 is specified for solid samples — rock, soil, core, ceramics and pressed powders.
How should powder samples be prepared?
Pressed pellets give the most repeatable results; loose soil can be measured with more scatter. Consistent preparation matters more than instrument settings.
Does it need radiation licensing?
No — LIBS uses a laser, not an X-ray tube. That is one reason exploration teams prefer it for remote field campaigns.
Put it to work
Send the material, not just the model number.
Tell us the alloy or element set, the sample form and the decision the reading has to support. We will confirm whether SciAps Z-903 is the right instrument — and say so when it is not.