Permeability · 0–2450 / Foundry process control
STD-IIIIntelligent Air Permeability Tester
A touchscreen air permeability tester for green and dry sand specimens.
STD-III
Configuration and sensor set confirmed at quotation.
01 / Why this configuration
Built around a real measurement decision.
The STD-III measures the permeability of standard 50 × 50 mm sand specimens. It displays the permeability value, specimen pressure, and test record on a 4.3-inch touchscreen.
A touchscreen air permeability tester for green and dry sand specimens. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.
02 / Configuration
Key specifications.
Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.
Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.
Request a configuration| Specimen | Ø50 × 50 mm |
|---|---|
| Fan power | 26 W |
| Fan pressure | 1000 Pa |
| Permeability range | 0–2450 |
| Orifice | 1.5 mm / 0.5 mm |
| Pressure accuracy | 1000 ±10 Pa |
| Power | AC 220 V / 50 Hz |
Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.
03 / Where it fits
Applications and materials.
Foundry process control supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.
See how we support the installation- Green sand permeability
- Dry sand permeability
- Moulding sand control
- Sand laboratory routine
- Incoming sand evaluation
Typical materials
If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.
Before you specify
STD-III — practical answers.
Still deciding? Send the material and the measurement target — we will reply with a practical next step.
Ask an application engineerWhat is the STD-III used for?
A touchscreen air permeability tester for green and dry sand specimens. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.
Which materials and sample forms does the STD-III cover?
Typical materials: Green sand, Dry sand, Core sand, Reclaimed sand. Typical tasks: green sand permeability, dry sand permeability. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.
What are the key specifications of the STD-III?
Starting point: specimen Ø50 × 50 mm; fan power 26 W; fan pressure 1000 Pa. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.
How is the configuration confirmed before ordering?
Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.
Put it to work
Configure STD-III around your material.
Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.