Gas evolution · 0–200 ml / Foundry process control
SFL-IISIntelligent Gas Evolution Tester
A touchscreen gas evolution tester for sand, coated sand, coatings, and moulding materials.
SFL-IIS
YuBoo Instrument / Luoyang, China
01 / Why this configuration
Built around a real measurement decision.
The SFL-IIS measures gas volume and gas evolution rate from a heated sand sample. It is used for green sand, coated sand, coatings, and other moulding materials.
A touchscreen gas evolution tester for sand, coated sand, coatings, and moulding materials. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.
02 / Configuration
Key specifications.
Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.
Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.
Request a configuration| Measuring range | 0–200 ml |
|---|---|
| Accuracy | ±1% |
| Control temperature | 1000 ±3 °C |
| Furnace maximum | 1150 °C |
| Power | ≤3.5 kW / AC 220 V |
| Control | PID / SCR program |
| Data storage | 100,000 records |
| Dimensions | 510 × 500 × 830 mm |
Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.
03 / Where it fits
Applications and materials.
Foundry process control supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.
See how we support the installation- Green sand gas evolution
- Coated sand gas volume
- Coating gas evolution
- Effective coal dust
- Moulding material evaluation
- Casting defect investigation
Typical materials
If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.
Before you specify
SFL-IIS — practical answers.
Still deciding? Send the material and the measurement target — we will reply with a practical next step.
Ask an application engineerWhat is the SFL-IIS used for?
A touchscreen gas evolution tester for sand, coated sand, coatings, and moulding materials. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.
Which materials and sample forms does the SFL-IIS cover?
Typical materials: Green sand, Coated sand, Resin sand, Coatings. Typical tasks: green sand gas evolution, coated sand gas volume. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.
What are the key specifications of the SFL-IIS?
Starting point: measuring range 0–200 ml; accuracy ±1%; control temperature 1000 ±3 °C. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.
How is the configuration confirmed before ordering?
Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.
Put it to work
Configure SFL-IIS around your material.
Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.