Low temperature · +30 to −60 °C / Mechanical testing
DWC-60Impact Specimen Low-Temperature Bath
A compressor-cooled bath for conditioning Charpy impact specimens from +30 °C down to −60 °C.
DWC-60
YuBoo Instrument / Luoyang, China
01 / Why this configuration
Built around a real measurement decision.
The DWC-60 brings impact specimens to the required test temperature and holds them there before transfer to the pendulum. A circulating bath and digital timer keep the conditioning step repeatable.
A compressor-cooled bath for conditioning Charpy impact specimens from +30 °C down to −60 °C. The final specification is matched to the material range, sample form, and reporting requirement of your laboratory or production line.
02 / Configuration
Key specifications.
Use these as a starting point. Utility requirements, calibration ranges, and acceptance criteria are confirmed against the final configuration.
Have the material list or a drawing? Send it with the application so the configuration can be reviewed properly.
Request a configuration| Temperature range | +30 to −60 °C |
|---|---|
| Stability | ±0.5 °C |
| Cooling | Dual compressor, circulating bath |
| Working volume | 120 × 120 × 70 mm |
| Specimen capacity | >60 bars (10 × 10 × 55 mm) |
| Timer | 1–99 min |
| Coolant | Ethanol or non-freezing fluid |
| Power | 220–240 V / 1.5 kW |
Indicative configuration information. Final datasheet and performance specification are issued with the quotation and confirmed at order.
03 / Where it fits
Applications and materials.
Mechanical testing supports decisions across incoming material, production control, and final verification. The right method depends on the question the result has to answer.
See how we support the installation- Charpy low-temperature conditioning
- Impact specimen cooling
- Sub-zero impact tests
- Heat-treatment comparison
- Welded joint toughness
- Laboratory specimen preparation
Typical materials
If your alloy or sample form is not listed, send the details. Configuration is not limited to the examples shown here — but every recommendation should be checked against the actual material and measurement target.
Before you specify
DWC-60 — practical answers.
Still deciding? Send the material and the measurement target — we will reply with a practical next step.
Ask an application engineerWhat is the DWC-60 used for?
A compressor-cooled bath for conditioning Charpy impact specimens from +30 °C down to −60 °C. The configuration is matched to the material range, sample form and reporting requirement of the laboratory or production line.
Which materials and sample forms does the DWC-60 cover?
Typical materials: Steel impact specimens, Cast iron, Aluminium alloys, Welded joints. Typical tasks: charpy low-temperature conditioning, impact specimen cooling. If the material or sample form is not listed, send the details before committing — the configuration is not limited to the examples shown.
What are the key specifications of the DWC-60?
Starting point: temperature range +30 to −60 °C; stability ±0.5 °C; cooling Dual compressor, circulating bath. These figures are indicative; utility requirements, calibration ranges and acceptance criteria are confirmed with the final configuration.
How is the configuration confirmed before ordering?
Send the material list, the sample form, the standard and the decision the result has to support. We confirm the configuration in the quotation, and a sample test can be arranged where the result is critical.
Put it to work
Configure DWC-60 around your material.
Send the alloy, sample form, elements of interest, and the decision the result needs to support. We will recommend a configuration and confirm the next step.